SUPERTHERM ®
"R" - Value Fairy Tale
The Myth of Insulation Values

One of the fairy tales of our time is the "R-value." The "R-value" is touted to the North American consumer ( all other countries in the world use K value ) to the point where it has taken a "chiseled in stone" status. The saddest part of the fairy tale is the R-value by itself is almost a worthless number.

It is impossible to define an insulation with a single number. It is imperative we know more than a single "R" number. So why do we allow the R-value fairy tale to be perpetuated? I don't know. I don't know if anybody knows. It obviously favors fiber insulation. Consider the R-value of an insulation after it has been submersed in water or with a 20 mile per hour wind blowing through it. Obviously the R-value of fiber insulations would go to zero or less. Under the same conditions, the solid insulations would be largely unaffected. Again R-value numbers are "funny" numbers. They are meaningless unless we know other characteristics.

None of us would ever buy a piece of property if we knew only one dimension. Suppose someone offered a property for $10,000 and told you it was a seven. You would instantly wonder if that meant seven acres, seven square feet, seven miles square, or what. You would want to know where it was -- in a swamp, on a mountain, in downtown Dallas. In other words, one number cannot accurately describe anything. The use of an R-value alone is absolutely ridiculous. Yet we have Code bodies mandating R-values of 20's or 30's or 40's. A fiber insulation having an R-value of 25 placed in a house not properly sealed will allow the wind to blow through it as if there were no insulation. Maybe the R-value is accurate in the tested material in the lab, but it is not even remotely part of the real world. We must start asking for some additional dimensions to our insulation. We need to know its resistance to air penetration, to free water, and to vapor drive. What is the R-value after it is subjected to real world conditions?

The R-value is a fictitious number supposed to indicate a material's ability to resist heat loss or heat load. It is derived by taking the "k" value of a product and dividing it into the number one. The "k" value is the actual measurement of heat transferred through a specific material.

Test to Determine the R-Value
The test used to produce the "k" value is an ASTM test. This ASTM test was designed by a committee to give us measurement values that hopefully would be meaningful. A major part of the problem lies in the design of the test. The test favors the fiber insulations -- fiberglass, rock wool, and cellulose fiber. Very little input went into the test for the solid insulations, such as foam glass, cork, expanded polystyrene, urethane foam and now ceramic insulation coatings such as SUPERTHERM ®.

The test does not account for air movement (wind) or any amount of moisture (water vapor). In other words, the test used to create the R-value is a test in non-real-world conditions. For instance, fiberglass is generally assigned an R-value of approximately 3.5. It will only achieve that R-value if tested in an absolute zero wind and zero moisture environment. Zero wind and zero moisture are not real world. Our houses leak air, all our buildings leak air, and they often leak water. Water vapor from the atmosphere, showers, cooking, breathing, etc. constantly moves back and forth through the walls and ceilings. If an attic is not properly ventilated the water vapor from inside a house will very quickly semi-saturate the insulation above the ceiling. Even small amounts of moisture will cause a dramatic drop in fiber insulation's R-value -- as much as 50 percent or more. The Canadian Roofing Association performed a study and determined that just 1.5% moisture content reduces the R value in bulk insulations by over 35%. 1.5% moisture is breathing on it. That means by the time you install the R19 fiberglass batt the insulation effectiveness is actually equivalent to R12 or less..

Vapor Barriers
We are told, with very good reason, that insulation should have a vapor barrier on the warm side. Which is the warm side of the wall of a house? Obviously, it changes from summer to winter -- even from day to night. If it is 20 F below zero outside, the inside of an occupied house is certainly the warm side. During the summer months, when the sun is shining, very obviously the warm side is the outside. Sometimes the novice will try to put vapor barriers on both sides of the insulation. Vapor barriers on both sides of fiber insulation generally prove to be disastrous. It seems the vapor barriers will stop most of the moisture but not all. Small amounts of moisture will move into the fiber insulation between the two vapor barriers and be trapped. It will accumulate as the temperature swings back and forth. This accumulation can become a huge problem . We have re-insulated a number of potato storage's, which originally were insulated with fiberglass having a vapor barrier on both sides. Within a year or two the insulation would completely fail to insulate. The moisture would get trapped between the vapor barriers and saturate the fiberglass insulation to the point of holding buckets of water. Fiber insulation needs ventilation on one side; therefore, the vapor barrier should go on the side where it will do the most good. SUPERTHERM ® is also a vapour barrier therefor it is always facing the warm side.

At very cold temperatures, when the temperature difference across the attic insulation reaches a certain critical point, convection within the insulation can reduce R-value.

Nisson, J.D. Ned, JLC, "Attic Insulation Problems In Cold Climates" March 1992, pp. 42-43

convection losses in lose Fill Insulation

We understand air penetration through the wall of the house. In some homes when the wind blows, we often can feel it. But what most people, including many engineers, do not realize is that there are very serious convection currents that occur within the fiber insulations. These convection currents rotate vast amounts of air. The air currents are not fast enough to feel or even measure with any but the most sensitive instruments. Nevertheless, the air is constantly carrying heat from the underside of the pile of fibers to the topside, letting it escape or carrying it from the topside to the underside and letting it penetrate. If we seal off the air movement, we generally seal in water vapor. The additional water often will condense (this now becomes a source of water for rotting or rusting of the structure and the growth of mold which is an air quality \ health issue - think of the " Leaky Condo " fiasco ). The water, as a vapor or condensation, will seriously decrease the insulation value -- the R-value. The only way to deal with a fiber insulation is to ventilate. But to ventilate means moving air which also decreases the R-value.

Air Penetration
The filter medium for most furnace filters is fiberglass -- the same spun fiberglass used as insulation. Fiberglass is used for an air filter because it has less impedance to the airflow, and it is cheap. In other words, the air flows through it very readily. It is ironic how we wrap our house in a furnace filter that will strain the bugs out of the wind as it blows through the house. There are tremendous air currents that blow through the walls of a typical home. As a demonstration, hold a lit candle near an electrical outlet on an outside wall when the wind is blowing. The average home with all its doors and windows closed has a combination of air leaks equal to the size of an open door. Even if we do a perfect job of installing the fiber insulation in our house and bring the air infiltration very close to zero from one side of the wall to the other, we still do not stop the air from moving through the insulation itself vertically both in the ceiling and the walls.

The best-known solid insulation is expanded polystyrene. Other solid insulations include cork, foam glass, polyisocyanate or polyisocyanurate board stock and ceramic insulation coatings. Each of these insulations is ideally suited for many uses. Foam glass has been used for years on hot and cold tanks, especially in places where vapor drive is a problem. Cork is of course a very old standby often used in freezer applications. EPS or expanded polystyrene is seemingly used everywhere from throw away drinking cups and food containers to perimeter foundation insulation, masonry insulations, and more. Urethane board stock is becoming the standard for roof insulation, especially for hot mopped roofs. It is also widely used for exterior sheathing on many of the new houses. All of the solid insulations will perform far better than fiber insulations whenever there is wind or moisture involved. SUPERTHERM ® will perform the best of all.

Most of the solid insulations are placed as sheets or board stock. They suffer from one very common problem. They generally don't fit tight enough to prevent air infiltration. It does not matters how thick these board stocks are if the wind gets behind them. We see this often in masonry construction where board stock is used between a brick and a block wall. Unless the board stock is actually physically glued to the block wall, air will infiltrate behind it. In this case, as the air flows through the weep holes in the brick and around the insulation it is rendered virtually useless. Great care must be exercised in placing the solid insulations. The brick ties need to be fitted at the joints and then sealed to prevent airflow behind the insulation.

The only commonly used solid insulations that absolutely protect themselves from air infiltration are the spray-in-place insulations ie. SPF or CERAMIC INSULATION COATINGS such as SUPERTHERM ®. When properly applied the bonding will effect a total seal. This total seal is almost impossible to overestimate. In my opinion most of the heat loss in the walls of the home have to do with the seal rather than the insulation.

For physical reasons, heat does not conduct horizontally nearly as well as it does vertically. Therefore, if there were no insulation in the walls of the homes, but an absolute airtight seal, there would not necessarily be a huge difference in the heat loss. This would not be the case if the insulation were missing from the ceiling. Air infiltration can most effectively be stopped with spray-in-place insulations such as SUPERTHERM ®. It is the only material (properly applied) that will fill in the corners, the cripples, the double studs, bottom plates, top plates, etc. The R-value of a material is of no interest or consequence if air can get past it.

"There is a problem with loose-fill fiberglass attic insulation is cold climates. It appears that, as attic temperature drops below a certain point, air begins to circulate into and within the insulation, forming "convective loops" that increase heat loss and decrease the effective R-value. At very cold temperatures ( -20°F \ -28.89°C ), the R-value may decrease by up to 50%."

r value vs temp

In full-scale attic tests at Oak Ridge national Laboratory, the R-value of 6 inches of cubed loose-fill attic insulation progressively fell as the attic air temperature dropped. At -18 F ( -27.78C ), the R-value measured only R-9. The problem seems to occur with any low-density, loose-fill fibrous insulation.

Nisson, J.D. Ned, JLC, "Attic Insulation Problems In Cold Climates" March 1992, pp 42-43

R-value tables are truly part of the "Fairy Tale." They show the solid and the fiber insulations side by side, implying they can be compared. The fact is, without taking installation conditions into account, comparisons are meaningless. Spray-in-place insulation such as SUPERTHERM ® provides its own vapor barrier, water barrier, and wind barrier. None of the other insulations are as effective without special care taken at installation. The fiber insulations must be protected from wind, water and water vapor. Again the tables need a second table to state installation conditions.

Understanding the two purposes of insulation gives a standard to measure the insulations:

I. Heat loss
There is a little understood part about insulation that needs to be covered. There is a substantial difference between insulation for temperature control and insulation for heat loss control. More insulation is not necessarily cost effective. There is a point where more insulation is pointless from a total heat loss perspective.

Where circumstances demand thinner walls or roofs, SUPERTHERM ® -- with its superior insulating capability -- makes it possible to reduce the thickness of the insulation component with no loss of thermal resistance. Or the thermal resistance of an assembly can be increased without enlarging the size of the member. SUPERTHERM ® helps to offset the design restrictions imposed by the fact that most building materials are constant in thickness and weight.

Thermal diffusivity and Heat Sinks
It should be noted that when SUPERTHERM ® is used on the exterior of a heat sink, such as concrete ( see Lower Nicola Ice Arena and Alberni Valley Multiplex ), the actual effective R-value is approximately doubled. A heat sink is any substance capable of storing large amounts of heat. Most commonly we think of concrete, brick, water, adobe and earth as heat sink materials used in building. The property of a heat sink to act as an insulation is called Thermal Diffusivity.

The simple explanation for the way it works is: As the temperature of the atmosphere cycles from cold to hot to cold to hot the heat sink absorbs or gives up heat. But because the heat sink can absorb so much heat it never catches up with the full range of the cycle. Therefore, the temperature of the heat sink tends to average. Large heat sinks will average over many days, weeks or even months.

An example is the adobe hacienda with its 2 to 6 foot thick walls. By the time the adobe walls begin to absorb the daytime heat it is nighttime and the same heat then escapes into the cooler night. Therefore the temperature would average. Because the mass of the adobe is so large the temperature averages over periods of months. Adobe acts as a bulk insulation even though adobe has a minimal “R” value.

SUPERTHERM ®'s thickness beyond 10 mils DFT is practically immaterial. We use 10 mils DFT for most of our construction. Obviously the first few mils takes care of the wind and water. The balance of the mils adds the thermal protection.

II. Surface temperature control
Surface temperature control is the second reason for insulation. In many cases it is the most important reason for the insulation.

Buildings insulated with 10 mils DFT of SUPERTHERM ® would hold the temperatures properly, just as well as the buildings insulated with 20 mils DFT. The difference came in the condensation. Ice Arena's and cold storage's, for example, are at very high humidity levels. Surfaces coated with the 10 mils DFT of SUPERTHERM ® or EPOXOTHERM ® would sometimes still experience condensation and would require additional thickness to control depending on the dew point differential ie. the surface temperature of a Liquid ammonia line or tank at - 35°C to -70°C and the ambient surrounding temperature and other environmental conditions such as relative humidity.

Underground housing — surface temperature control vs. heat loss control. see " Insulating Basement Walls "
Most underground housing is in trouble from mold and mildew growth. The cause is not enough insulation to control interior surface temperatures. Rarely is there a problem with total heat loss. Water vapor condenses on the surface allowing mold to grow. Mold makes people sick. The only solution is lots of insulation for temperature control and ignore total heat loss.

My experience is that R-value tables can be used as indicators. They need modifications to make them equal to real world conditions. There needs to be allowances made. They must show equivalents. These equivalents will be more like 10/1000" of ceramic insulation coating equal to six inches of fiberglass or one inch of spray-in-place urethane equal to four inches of fiberglass, in a normal installation. Footnotes to the table will need to define degradation of insulations in real world conditions. Only then will the "R-value" Fairy Tale become a real world success story. These real world conditions have finally started to be addressed in the ASHRAE 90.1 CODE COMPLIANCE.

In addition to the aforementioned inherent thermal deficiencies in fiberglass, there is also the possibility of some inherent health concerns. For further information regarding the very real possibility of fiberglass being as carcinogenic as asbestos visit the Fiberglass Information Network.