SUPERTHERM ®
ARCHITECTURAL SPECIFICATIONS
|
| B117 | 450 Hour Salt Spray ( Fog ) | Passed |
| C177 | Thermal Conductivity | Passed |
| C236-89 (93) | Thermal Transmittance \ Conductance | Passed |
| C411 | High Temperature Surface Performance | Passed |
D412 |
Tensile Properties -.041 thickness = 13,248 psi |
Passed |
D522
|
Mandrel Bend on metal or rubber materials |
Passed
|
| D1653 | Water Vapor Permeability | Passed |
| D3273-82T | Fungal Resistance | Passed |
| D3274 | Fungal Resistance | Passed |
| D4060 | Abrasion Resistance | Passed |
| E108 | Standard Test Method for Fire Tests of Roof Coverings | Passed |
| E84 |
Flame Spread \ Smoke Developed -Class "A" rating (or Class"I" or Class "1") |
Passed |
E84-89a
|
Flame Spread \ Smoke Developed -Flame Spread Index "0" -Smoke Developed "0" |
Passed
|
| E96 | Water Vapor Transmission | Passed |
| E903-96 | Reflectance | Passed |
| E1269 | Heat Capacity by Differential Scanning Calorimeter | Passed |
| E1461 (92) |
Thermal Diffusivity \ Conductivity by Flash Method - Blocked 91% of Heat BTU Conduction |
Passed |
| G53 | 1000 Hours UV Exposure | Passed |
.2 SUPERTHERM ® has other Registrations and Certifications :
| Energy Star Program | Approved Partner |
| Approved and accepted as an energy partner for saving energy | |
| Passed ASTM E903-96 Reflectivity 80% | |
| Only 1% Reduction in Reflectivity over 3 years | |
| Only 3% Reduction in Reflectivity over 10 years | |
| This test is for Reflectivity only and does not include any insulation abilities | |
| ICC (International Code Council) | Approved |
| Formally consolidates approvals for: | |
| BOCA (Building Officials Code Administration) | |
| ICBO (International Conference of Building Officials) | |
| SBCCI (Southern Building Code Congress International) |
| Section 07200 - Insulation: - Thermal Insulating Materials Section 723.2 Exposed installations - Thermal Insulating Materials Section 723.3 Concealed installations - Interior Finish Section 803.2 Classification - Insulation Section 604.3 Coverings and linings - 1998 International Mechanical Code |
|
| Factory Mutual | Approved |
| - Tested and approved
for Roofing and all other applications - Process of Listing |
|
| USDA (United States Department of Agriculture) | Approved |
| - Letter of Authorization from USDA Product Safety Branch - Letter of Written Certification as Accepted by USDA from manufacturer |
|
| CFIA (Canadian Food Inspection Agency) | Approved |
| - Accepted Construction Materials, Packaging Materials and Non-Food Chemical Products |
|
| DNV ( Det Norske Veritas ) | Certified |
| - Passed DNV Audit and
DNV Compliance - Approved for world-wide salt water and maritime use - Tested Low Flame Spread, no excessive smoke, nor toxic product |
|
| IMO (International Maritime Organization) | Passed |
| - IMO A. 653 (16) Flame spread for bulkhead, wall and ceiling linings |
|
| MSC ( Marine Safety Counsel ) | Passed |
| - MSC.41 (64) Toxic Gas
generation using Colorimetric Gas Detector Tubes - Met all toxic gas requirements |
|
| NASA ( National Aeronautics and Space Administration | Passed |
| - NASA 8060.1B/C, Test 1 Flammability Test "0"
Flame Spread - NASA 8060.1C, Test 7 Toxic Off-gassing "K" Rating |
|
| JIS ( Japanese Institute of Standards ) | Passed |
| - JIS A 5759 Reflectivity Light and Radiation - Light Reflectivity Ratio 92.2 - Long Wave Radiation ( Infrared ) 99.5 |
|
| - GB/T 1771-91 | Resistance to Salt Fog (2000 hours) | Passed |
| - GB/T 1866-88 | Manual Aging (2000 hours) | Passed |
| - GB/T 10834-88 | Resistance to Salt Water (1000 hours) | Passed |
| - GB/T 5219-85 | Adhesion (pulling apart method) | 4.07Mpa |
| - GB/T 1733-93 | Boiling Water Immersion | 8 hours |
3. EXECUTION
3.1
PROTECTION \ PREPARATION OF SUBSTRATE
.1 Protect adjacent surfaces and equipment from damage by over-spray, fallout and dusting. Mask adjacent work as required.
.2 Repair any damaged areas first by caulking, patching, sealing, grouting, welding, taping, priming, etc.
.3 Clean substrate to remove dirt, dust, grease, oil, waxy substances, release agents, loose material such as flaking paint or rust or other matter which would affect bond of ceramic insulation coating. Surfaces must be clean, dry and sound before application. High-pressure water blasting with TSP is as effective as light sand blasting in removing loose or old flaking paints or corrosion. As a rule, "a coating is only as good as the surface it covers." Old paints can remain if bonded solidly to surfaces.
3.2
ENVIRONMENT
.1 Application temperatures range from a minimum of 50F \ 10C to a maximum of 194F \ 90C but the optimum application temperature is 72F \ 22C.
.2 Never apply if it’s raining or there is a chance of rain the day of application.
If applied when humidity is high or it rains constantly for 3-4 days after SUPERTHERM ® is applied you may notice some bubbling
effects on the coating. DO NOT PUNCTURE these bubbles. This is normal as
the formula is water based and is absorbing the moisture and, therefore
forming bubbles. After the rain stops, the sun will dry out the coating
and allow it to cure down naturally. As the sun draws out the moisture,
the bubbles will settle down and allow the coating to adhere in its normal
dry down without problem.
3.3
APPLICATION
.1 SUPERTHERM ® can bond to metal, wood, masonry and other porous surface substrates, and can be best applied by airless or air pot sprayer, roller and by brush.
.2 If rolling, it may take two coats to apply required mils. A 3/4-inch nap roller is best.
.3 Spraying requires a .028 - .032 steel carbon tip. Remove all filters from spray equipment before using.
.4 Do not apply very thick
on a single coat. If thickness is desired, apply in multiple coats. A thick
coat will allow the top-coating surface to dry before the bottom thus creating
cracks in the coating.
3.4
COVERAGE
.1 SUPERTHERM ® is applied at a rate of 100 square feet per gallon. This gives a mil thickness of 16 mils WFT that equals 10 mils DFT being 68% solids by volume.
.2 On a horizontal substrate this is easily achieved in one coat using the cross hatch method of up and down and side to side.
.3 On vertical substrates
it is possible to apply 16 mils WFT in one coat but it's easier and better
to apply it in 2 coats of 8 mils WFT each. This prevents any possible sag
by going a little too thick and allows you to cross hatch (side to side
then up and down) to achieve a perfect seal.
3.5
DRYING \ CURING TIME AND RECOAT WINDOWS
.1 SUPERTHERM ® is a waterborne coating which contains no co-solvents and dries by evaporation.
.2 Drying time is generally 1 hour to touch and 2 hours to recoat but these times will vary depending on relative humidity and ambient temperature. More dry time is required in a very cool or damp climate.
.3 SUPERTHERM ® completely cures is 14 – 21 days again depending on relative humidity and ambient temperature.
.4 SUPERTHERM ® contains 8% water. Water is a
thermal conductor as opposed to a thermal resistor consequently the performance
increases over time until all the water has evaporated out of the coating.
3.6
COLOURS
.1 First and foremost colour of course has an effect on heat build up. The darker the colour the more heat it absorbs.
.2 Unlike paint, which contains 25% - 50% water, SUPERTHERM ® only has 8% water for a high quality water based universal tint to work with. Consequently SUPERTHERM ® may be tinted to a light pastel or earth tone. The exception to this is GREY because the tint required is black which has a tendency to cover the ceramics and affect the performance. The least desirable thing is black providing heat conductance all the way through the coating.
.3 If a dark colour is desired then the recommendation is to double the mils to 16 – 20 mils DFT and topcoat with the dark colour. At least this way the ceramics will throw the absorbed heat back into the topcoat.
.4 Even with a pastel colour it's better to topcoat but then you only need 8 - 10 mils DFT of SUPERTHERM ®