APPLICATION METHOD:
Surfaces must be clean and dry before application. Any surfaces with loose or flaking old paints or corrosion must be removed before applying. High-pressure water-blasting is as effective as light sand-blasting in removing loose or flaking surfaces if you use 5000 psi. As a rule, "a coating is only as good as the surface it covers." Grease, oil, waxy substance, dirt, etc. must be cleaned from surfaces. Old paints can remain if bonded solidly to surfaces. NON-SKID II can bond to metal, masonry, wood and other porous surface substrates. NON-SKID II can be applied best by brush, squeegee or foam applicator. Airless sprayers can be used using a 32-thousandth tip and removing all in-line and/or handle filters.

International Concrete Repair Institute - Concrete Surface Preparation Guidelines

Shipping identification: Flammable liquid, DOT identification #UN-1263.
Clean up: Solvent wash to clean equipment. Use MEK or MIBK to clean equipment. COMES READY TO MIX AND USE, NO NEED TO DILUTE OR THIN.
IMPORTANT: Floor surface must be clean and completely free of moisture and residues of any kind. It is preferable that the first coat is mixed 25/75 with MEK solvent to anchor then apply the top coat as normal.

Catalyst ratio: This is a two-part mixture. Mixed 1 part cure agent to 3 parts base. Mix on job site before application. Pot life is 6-8 hours at 77 degrees Fahrenheit.
Packaged unit: Shipped as a 4-gallon kit. Three-gallon base in a pail with a gallon can of curing agent separate. On job site, pour the gallon of curing agent into the 3-gallon pail of base and mix to have a finished product mixture of 4 gallons. Let set for 30 minutes, then apply

Vehicle type: Aliphatic Polyurethane
Dry time: To touch - 60 minutes To handle - 4 hours To recoat - 2 hours
Pigment type: Varies with color
Shipping identification: Flammable liquid, DOT identification #UN-1263.
Solids by volume: 44%.
Cures by: Chemical reaction
Weight per gallon: 9.8 lbs.
Application: Brush, roller, spray. if spraying, must use Airless sprayers can be used using a 32-thousandth tip and removing all in-line filters.
Recommended film thickness: @ 250sq.ft. Wet: 5-7 mils (wet mil gauge recommended) Dry: 2-3 mils/coat @100 sq.ft. Wet: 12-15 mils Dry: 5-7 mils/coat (1 mil = 1/1000 inch)

SAFETY PRECAUTIONS:
As per OSHA regulations for painting, the applicator must, at all times during use: Wear skin and eye protection. Do not take internally. Avoid contact with eyes. If solution does come in contact with eyes, flush immediately with water and contact a physician for medical attention. Avoid prolonged contact with skin or breathing of spray mist.