APPLICATION
METHOD :
This material is designed primarily as a coating for application
on clean concrete surfaces. For maximum adhesion, always etch concrete with a
25% solution (in water) of muriatic acid, and allow to stand for 15 minutes. Then
flush thoroughly with clean water and allow to dry completely before coating.
Unlike solvent-borne sealers, WATER BASED EPOXY
(NS) may be applied to damp concrete surfaces without fear of delamination
and adhesion loss.
International Concrete Repair Institute - Concrete Surface Preparation Guidelines
Dry
Time: To touch: 45-60 minutes Dry hard:8 hours To recoat:4-6 hours (to touch)
Recommended film thickness: 3-6 mils dry (75-150 microns) Each coat - 245
sq. ft. (22.78 M2) 6.5 mils (162.5 microns) wet 3.0 mils (wet mil gauge recommended)
(75 microns) dry
Solvent: water
Gloss: full gloss
Heat-resistance:
225F (107C)
Sec 3.2 Inside Painting System #1
Pot Life: 6-8 hours
Mix ratio: 1 part curing agent to 8 parts base (80% of pint to 90% of a gallon)
Induction Period: 30 minutes 8.9
Minimum storage temperature: 32F (0
degrees C)
VOC: 1.2 lbs./gallon (144 grams/liter
IMPORTANT:
Do not take internally. Avoid contact with eyes. If solution does come in contact
with eyes, flush immediately with water and contact a physician for medical attention.
Users of organic coatings such as this material should always wear Bureau of Mines-approved
paint vapor respirator, which employs two-stage filtering/i.e. cotton and charcoal